HEAVY COMPRESSION ENGINEERING 5–1,000 t ENQUIRY RANGE
CANISTERLOADCELLLOAD PATHS. ENGINEERED.Build your RFQ
Menu
CANISTER & ROCKER COLUMN LOAD CELLS

Canister load cells.
Clear load paths.

Canister load cells, self-restoring rocker columns and matched mounting hardware for weighbridges, silos and high-capacity compression testing.

5–1,000 tCapacity enquiry scope
H₁ / H₂ / RGeometry before selection
4 / 6 / 8 / 10Matched fleet requests
ROCKER COLUMN / LOAD INTRODUCTIONCLC-RCK
Canister load cell rocker conceptual load-path and dimension diagram
CONCEPTUAL GEOMETRY · NOT A MANUFACTURING DRAWING
Spherical ends. Matched cups. Controlled restoring action.
START WITH THE ASSEMBLYMoving weighbridge deckHeavy axial compressionReplacement cups & mountsMatch an existing column
THE COMPRESSION CATALOGUE

Canister load cell families,
defined by the load path.

Choose the mechanical interface first. Then align capacity, electronics and the evidence required for your project.

Canister load cell dimensions conceptual load-path and dimension diagram
CONCEPTUAL GEOMETRY · NOT A MANUFACTURING DRAWING
SELF-RESTORING GEOMETRY

Canister load cell movement needs a designed return path.

When a deck moves sideways, the rocker column tilts within its approved travel envelope. Matched spherical ends and receiver cups create a restoring action toward the vertical load path.

The actual tilt, radius and lateral displacement are model-specific. Check rods, stops, uplift restraint and structural clearances remain part of the system design.

Review seated-height and interface checks
TWO PROCUREMENT WORKFLOWS

Canister load cell fleets and high-force test assemblies

WEIGHBRIDGE / SILO

A matched column fleet

4, 6, 8 or 10 columns, upper and lower cups, debris gaiters, surge junction box and 15–30 m braided cable requests.

Build a fleet enquiry
HYDRAULIC JACK / PILE TEST

A controlled compression stack

100–1,000 t flanged canister, machined spherical top saddle, flat base plate and a defined calibration scope.

Build a test kit enquiry
BEFORE YOU SPECIFY

Canister load cell questions that affect the assembly

Can an 8 × 40 t canister load cell fleet weigh a 100 t truck?

It is an enquiry configuration, not a structural approval. Include deck dead load, gross load, unequal load distribution, impact, overload factors, supports and local weighing rules. The most heavily loaded cell governs.

Will digital canister load cells work with my existing indicator?

Only after checking the exact protocol, addressing, power supply, termination, firmware and calibration tools. An RS485 connector does not establish interoperability.

Canister load cell reference documents

Original-manufacturer and metrology references explain the engineering principles. They do not certify a CLC configuration.

Flintec RC3 manufacturer datasheet

Self-restoring column design, model-specific dimensions and surge-arrestor features. Refer to the exact capacity and drawing revision.

HBK C16A manufacturer product and drawing library

Self-restoring rocker pins, rotation stop, capacity and protection variants; these are original-manufacturer specifications.

HBK load application guidance

Load introduction and restoring geometry; assembly design still governs lateral restraint.

NIST Handbook 143, force calibration criteria

ASTM E74 and ISO 376 instrument-calibration methods; a five-point test alone does not establish compliance.